A plain-English guide to IIC, STC and Delta IIC for anyone choosing an underlayment for vinyl plank in a Hawaii condo, written for people hearing the word "soundproofing" for the first time.

By Borys Rasin, owner of Best Flooring Honolulu · Updated November 2026

Quick answer: replacing flooring in a Honolulu condo

  1. Get your building's flooring rule. Ask management for the house rules and the contractor packet; the sound rule is often in the packet. Our building-by-building list may already have it.
  2. Read which number it asks for. A lab IIC on a spec sheet, a field test after installation, or a specific product.
  3. Choose your floor first. Click vinyl plank, laminate, hardwood and tile each allow different underlayments.
  4. Choose the underlayment that your floor's installation manual allows and that meets the rule on paper. If you want the floor to be truly quiet, go thicker where the floor allows it.
  5. Send the board the spec sheet or test report and wait for written approval before work starts.

Not sure? Book a free in-home estimate or call (808) 210-4807 and send us your building's rule.

In this guide: IIC, STC, Delta IIC · The hidden ceiling · Underlayment types · Cost · Getting approved · Which floors work over rubber · Our recommendation · FAQ

Key takeaways

  • IIC measures how well a floor stops footstep noise. STC measures how well it stops voices and TV. Higher is quieter.
  • An IIC number describes the whole floor-ceiling assembly, not the underlayment alone.
  • Most "IIC 70+" underlayment claims were tested with a suspended ceiling under the slab, which adds about 10–20 points. Many older Honolulu concrete condos don't have one.
  • Delta IIC is the fair way to compare underlayments. On that test, 10 mm Regupol Sonus Core rubber adds 28 points with vinyl plank; thin foam pads add 22–26.
  • Published Honolulu AOAO rules ask for IIC 62 to 70. Rules that give one number without naming the test setup tend to reward the thinnest foam pads instead of the best-performing ones. See our building-by-building list.

Two underlayments, one strange result

Picture this. In one hand I'm holding a 1.5 mm foam underlayment. Spec sheets for popular pads like this list IIC 71 to 73; call it 72. It costs about a dollar per square foot. In the other hand I'm holding a 10 mm vulcanized rubber underlayment, Regupol Sonus Core 10. Its test report says IIC 59, and it costs around three dollars per square foot.

Both were tested with vinyl plank on top. The rubber is almost seven times thicker, costs about three times more, and is made from a denser, longer-lasting material. So how can the thin foam score 13 points higher?

A thin 1.5 mm foam pad labeled IIC 72 next to a thick 10 mm rubber pad labeled IIC 59 1.5 mm foam 10 mm rubber plank · foam 1.5 mm · concrete plank · rubber 10 mm · concrete IIC 72 under $1 / sq ft IIC 59 about $3 / sq ft ? Both tested with vinyl plank on top. Thickness drawn roughly to scale.
Drawing 1. The paradox. The thinner, cheaper pad shows the bigger number.

Is the foam secretly better? Is the rubber overpriced? Neither. The answer is that the two numbers come from two different tests. Once you see how IIC is measured, the mystery goes away, and you'll know how to choose an underlayment that actually keeps your downstairs neighbor happy.

What is soundproofing?

Soundproofing means reducing how much noise passes from one space to another. In a condo, it usually means keeping your noise out of your neighbor's unit, especially the unit below you. Nothing makes a floor completely silent. Soundproofing is about making noise quieter, and sound ratings tell you how much quieter.

Every floor is a stack of layers. From the top down in a typical Honolulu condo: the flooring you walk on, an underlayment, the concrete slab, and the ceiling of the unit below. Each layer either passes sound along or soaks some of it up.

Why do condo HOAs require soundproofing?

Most older Hawaii condo towers were built with carpet. Carpet and its thick pad are soft, so footsteps barely reached the unit below. When owners replace carpet with vinyl plank, laminate, tile or hardwood, the floor becomes hard. Every heel strike, dropped spoon and chair leg now goes straight into the concrete and comes out as a thump downstairs.

Carpet absorbs footsteps; hard vinyl plank without a good underlayment sends them into the slab and the unit below Old carpet New hard floor soft pile + thick pad soak up the step hard surface passes the step into the slab
Drawing 2. Why the rules exist. Carpet hid footstep noise; hard floors don't, so associations require a sound-rated underlayment.

Noise complaints between neighbors are one of the most common fights in condo living, and they are expensive to fix after the floor is in. So associations (called AOAOs in Hawaii) write flooring rules: you may install a hard floor only with an approved underlayment that meets a minimum sound rating. That's a reasonable goal. The trouble, as you'll see, is in how the number is written.

IIC vs STC vs Delta IIC: the three numbers

A condo floor carries two kinds of noise to the unit below.

  • Impact noise is anything that hits the floor: footsteps, a dropped spoon, a chair sliding, a dog running. The floor itself gets struck and vibrates. IIC (Impact Insulation Class) rates how well a floor stops this.
  • Airborne noise travels through the air first: voices, a TV, music. STC (Sound Transmission Class) rates how well a wall or floor stops this.

For hard floors like vinyl plank, impact noise is the problem neighbors complain about. That's why HOAs focus on IIC, and why an underlayment matters: it is the cushion between your heel and the concrete.

What about STC? Airborne noise is stopped mostly by the heavy concrete slab, not by the underlayment, so changing the underlayment barely moves STC. If your rule lists an STC number too, the same test report usually shows it next to the IIC.

Footsteps on the floor create impact noise measured by IIC; voices and TV create airborne noise measured by STC Impact noise footsteps, dropped things, chairs rated by IIC Airborne noise voices, TV, music rated by STC concrete slab
Drawing 3. Footsteps hit the slab and shake it (IIC). Voices travel through the air (STC). Under vinyl plank, footsteps are what neighbors hear.

The whole family of sound ratings

You'll see more letters than IIC and STC on spec sheets and HOA rules. They all belong to two families, footstep noise and airborne noise, and each family has a lab version, a field version and an improvement version:

Two families of sound ratings: impact (IIC, FIIC or AIIC, Delta IIC) and airborne (STC, FSTC or NNIC) Footstep (impact) noise Voices & TV (airborne) IIClab testASTM E492 FIIC / AIICfield testASTM E1007 ΔIICimprovementASTM E2179 STClab testASTM E90 FSTC / NNICfield testASTM E336 Lab test: built so sound can only go through the test floor. Usually the highest number. Field test: measured in a real building, side paths included. Usually lower. Improvement (ΔIIC): only what the underlayment and floor add. Best for comparing products. Code minimum between units: IIC 50 / STC 50 in a lab, 45 in the field.
Drawing 4. The rating family. When an HOA writes "IIC 72," ask which of these it means.

The higher the number, the quieter the floor. The scale is logarithmic, so every 10 points is a big change in how loud footsteps sound below. Roughly:

IIC scale from 25 to 80 with markers for bare slab, building code, rubber without ceiling, foam with ceiling and typical HOA requests 253545556575 28–35bare concrete 45code minimum,field test 50code minimum, lab 5910 mm rubber,no ceiling below 721.5 mm foam,with ceiling below HOAs ask 62–70
Drawing 5. Where the numbers sit. Bare concrete is around IIC 28–35. The building code minimum between condo units is IIC 50 in a lab and 45 in a field test. Published Honolulu AOAO rules ask for IIC 62 to 70.

Of all these, Delta IIC (ΔIIC) is the one most people have never heard of, and for choosing an underlayment it's the most useful. We'll get to it in a minute.

How IIC is actually tested

An IIC test needs two rooms stacked on top of each other. In the top room, a tapping machine with five small steel hammers pounds the floor at a steady rhythm. In the room below, microphones record how loud it is. The quieter it is downstairs, the higher the IIC.

Lab test: tapping machine on the floor of the upper room, microphone in the lower room tapping machine (5 steel hammers) microphone 6" or 8" concrete slab upper room lower room: how loud is it here?
Drawing 6. The standard lab test (ASTM E492). What's installed above and below the slab is part of the test, and it changes the score.

Here's the part almost nobody tells homeowners: the IIC number belongs to the whole floor-ceiling sandwich, not to the underlayment. The flooring, the underlayment, the slab thickness, and whatever is hanging under the slab in the room below all count. Change any layer and the number changes.

You can see it on a single spec sheet. OmniChoice Vapor Bloc, a 1.5 mm foam pad we sell, lists IIC 73 under vinyl plank and IIC 51 under ceramic tile. Same pad, 22 points apart, because the floor on top changed.

The hidden ceiling: where the extra 10–20 points come from

Read the fine print on any underlayment that claims IIC 70+ and you'll almost always find a line like "6-inch concrete slab with suspended ceiling." That means the lab hung a drywall ceiling on metal channels under the slab, with an air gap and often insulation. That ceiling is a second sound barrier, and it adds a lot of points on its own.

You can see it in Regupol's own published reports, where the product, the floor and the slab stay the same and only the ceiling changes. Sonus Core 10 under 1/4" ceramic tile on a 6" slab scores IIC 50 with no ceiling (test E1551.05) and IIC 62 with an insulated gypsum ceiling below (test E1551.08). Twelve points, and the underlayment didn't change at all.

Wood floors on an 8" slab show a bigger gap: Sonus Core 3 tested at IIC 54 under 1/2" solid hardwood with no ceiling (E1552.01) and IIC 74 under 1/2" engineered hardwood with an insulated gypsum ceiling (NGC 7011096). Those two floors are similar but not identical, so read that 20-point gap as a ballpark, not an exact measurement.

Same underlayment, same tile, same slab: IIC 50 with no ceiling below versus IIC 62 with an insulated gypsum ceiling No ceiling below Insulated ceiling below IIC 50 3-1/2" insulation + 5/8" gypsum below IIC 62 Regupol Sonus Core 10 · 1/4" ceramic tile · 6" concrete slab · same product both times
Drawing 7. The ceiling below did the work. Same underlayment, same tile, same slab: 50 without a ceiling, 62 with one (Regupol tests E1551.05 and E1551.08).

Now look back at Drawing 1. The foam pad's IIC 72 was measured with a suspended ceiling under a 6" slab. The rubber's IIC 59 was measured on a 6" slab with nothing underneath. The foam didn't win; it was given a ceiling to stand on.

Why this matters in Honolulu: many older concrete towers here have no suspended ceiling; the ceiling of the unit below is often the painted underside of your slab. So a spec sheet tested with a suspended ceiling describes a building you don't live in.

Lab versus your actual building

There's a second gap between the brochure and your condo. Labs are built so sound can only travel through the test floor. Real buildings leak: footsteps also travel sideways through the slab into walls, columns, pipes and the ceiling of the unit below. Acousticians call this flanking. Field tests, which measure your real unit, include it, and they usually come in lower than lab tests. That's why the building code itself accepts 45 in the field versus 50 in the lab.

Sound travels through the floor and also sideways through walls and columns in a real building Lab Your building one path: through the floor extra paths: walls, columns, pipes
Drawing 8. In a lab, footstep noise has one way down. In a real building it also escapes through walls and columns, so real-world scores come in lower.

Delta IIC: the fair way to compare underlayments

If the ceiling and the building change the score, how do you compare two underlayments fairly? With Delta IIC (ASTM E2179). The lab tests a bare concrete slab, then tests it again with the underlayment and flooring added, and reports only the improvement. No ceiling, no extra layers. It measures what the underlayment itself adds.

On that fair scale, using the makers' own published numbers:

Delta IIC bars: thin foam pads add 22 to 26 points, 10 mm rubber adds 28 points Foam pad A (1.5 mm) +22 Foam pad B (1.5 mm) +26 Rubber, Sonus Core 10 +28 0102030 Delta IIC = points the underlayment + floor add over bare concrete Foam: 1.5 mm pads sold for vinyl plank. Rubber: Regupol report, vinyl plank on 6" slab.
Drawing 9. Apples to apples, the rubber adds the most. The 13-point "win" for foam in Drawing 1 disappears once the ceiling is taken out of the comparison.

That's the honest picture. On a fair test, rubber does more than foam. It's not magic, a few points, but those points are real and they don't depend on a ceiling you don't have.

One more honest detail: thickness matters. The +28 is for 10 mm rubber. Regupol's 3 mm and 5 mm cores tested at Delta IIC 24 under the same kind of click vinyl on a 6" slab (IIC 56), about the same as thin foam. Thin rubber's advantage is that it doesn't flatten over the years; the big jump in quiet comes from the thicker cores, where your floor allows them.

And rubber keeps doing it

Sound performance on day one isn't the whole story. A 1.5 mm foam pad sits under every footstep, every table leg and every rolling chair for the life of the floor. Dense vulcanized rubber like Sonus Core is built to spring back under load, which is why it's used in commercial buildings, gyms and high-rise residential projects. When you're spending thousands on a new floor, the layer underneath shouldn't be the cheapest part of it.

Rubber vs foam underlayment (plus cork and felt) compared

Underlayments for vinyl plank, often sold as acoustic underlayment or soundproof underlayment, fall into a few families. They differ in what they're made of, how thick they are, how much sound they stop on a fair test, and how long they keep doing it.

Cross-sections of five underlayment types: PE or IXPE foam, XPS foam, felt, cork and rubber, drawn by thickness PE / IXPE foam1–2 mmΔIIC about 22–26 XPS foam1.5 mmΔIIC about 26 Felt2–3 mmsoaks up moisture Cork3–6 mmΔIIC about 22–23 Rubber3–12 mmΔIIC 24–28 Vinyl plank on top, concrete below. Thickness exaggerated for thin pads so they stay visible.
Drawing 10. The main underlayment families. ΔIIC values are from the makers' published reports for the products we stock.
Type Thickness Sound (ΔIIC, fair test) Moisture Holds up over time Price at BFH
PE / IXPE foam (Nroro SoundBarrier) 1–2 mm about 22–26 Closed-cell, resists water Thin foam can flatten under heavy furniture from $0.89 / sq ft
PU (frothed) foam (OmniChoice) 1.5 mm about 22 Vapor Bloc version has a built-in film Good $1.62–1.84 / sq ft
XPS foam (Lifeproof) 1.5 mm about 26 Closed-cell, resists water Stiffer than PE; can crush at point loads $1.78 / sq ft
Felt / fiber 2–3 mm varies, few fair tests Absorbs moisture; avoid on Hawaii concrete without a barrier Fair we don't sell it for condos
Cork and cork-foam (QEP, Eco Cork Foam) 3–6 mm about 22–23 Natural cork needs a vapor barrier on concrete Good $1.78–2.25 / sq ft
Rubber (Regupol Sonus Core, in stock) 3–12 mm 24–28 Rot-proof, won't absorb water Built to spring back under load 10 mm: $2.94 / sq ft

See every product in our underlayment for vinyl plank collection, plus cork underlayment and tile underlayment.

Our own budget pick: Nroro SoundBarrier

We also sell our own foam, Nroro SoundBarrier, a 1.5 mm pad at $0.89 per square foot. Its SGS lab report shows IIC 69 and STC 68, tested with SPC flooring on a 6" concrete slab with a drop ceiling below. We tell you that plainly because now you know what it means: it's a solid, affordable pad, and its numbers come from the same kind of ceiling test as the other foams. Choose it when your board accepts spec-sheet numbers and budget comes first. Choose Sonus Core rubber when you want the most real-world quiet and a pad that lasts as long as the floor.

What it costs: a 1,000 sq ft condo, foam vs rubber

Here's the underlayment cost for a typical 1,000 square foot condo floor, materials only, at our current prices:

Underlayment cost for 1,000 square feet: Nroro foam 890 dollars, typical 1.5 mm foam 950 dollars, Regupol Sonus Core 10 mm 2,940 dollars Nroro SoundBarrier foam $890 Typical 1.5 mm foam $950 Regupol Sonus Core 10 mm $2,940 Difference: about $2,000 for the whole condo, or $2 per sq ft. Materials only, before tax and adhesive.
Drawing 11. The rubber upgrade costs about $2,000 on a 1,000 sq ft floor, a fraction of the flooring and installation it sits under.

For context, a mid-range vinyl plank like our Nroro Hawaii Collection runs $4.39 per square foot, about $4,390 for the same 1,000 square feet before installation. The underlayment is the one layer you can't upgrade later without tearing the whole floor out, so this is the cheapest moment to choose well.

Want exact numbers for your unit? Book a free in-home estimate. We measure, check your building's rule, and quote floor plus underlayment together.

What actually makes a condo floor quieter

Every layer in the stack can help, but as an owner you only control some of them. Here's what each one does and who controls it:

Floor layers and who controls them: rugs and flooring and underlayment by the owner, the slab by the building, the ceiling below by the neighbor Rugs, felt padsyou · helps a little Flooringyou Underlaymentyou · ΔIIC 22–28 Concrete slabbuilding · fixed Ceiling belowneighbor · +10–20 The underlayment is the biggest sound upgrade an owner controls.
Drawing 12. Who controls which layer. A suspended ceiling helps a lot, but it's in your neighbor's unit. The underlayment is yours.

That's why the underlayment choice matters so much: it is the one big sound decision that is fully in your hands, and it is installed once for the life of the floor.

The HOA problem

Here's where it gets frustrating for homeowners. Many condo associations write a single number into their flooring rules. We read the governing documents of fifty Oahu buildings for our Honolulu condo flooring rules page: published requirements range from IIC 62 (Ilikai) and IIC 65 (Island Colony, Waikiki Banyan, Honolulu Park Place, Century Center) to IIC 70 after installation (Keola La'i). The rule usually doesn't say which test, which slab, or whether a ceiling was included.

Keola La'i shows the gap better than any example we could invent. Its house rules require "an Impact Insulation Class (IIC) rating of seventy (70) or greater ... after flooring installation." But when management actually checks a finished floor, it uses a field threshold of AIIC 53. The written rule and the field check use different numbers, which shows how far a lab figure and a real unit can sit apart. (Its pre-approved list includes Pliteq GenieMat RST10, a rubber mat we also carry.)

In a typical Honolulu tower with no suspended ceiling, no underlayment on its own can honestly deliver IIC 65 or 70 in your unit. The only products that "meet" the rule on paper are the ones whose spec sheets were tested with a suspended ceiling, and those are mostly the thinnest, cheapest foam pads. The rule meant to protect the neighbor below ends up steering owners toward the product that does the least.

Flow: HOA demands IIC 65, only ceiling-tested foam qualifies on paper, owner buys thin foam, neighbor still hears footsteps; better rule leads to rubber and a quieter floor HOA rule:"IIC 65 or higher" Only pads testedwith a ceiling qualify Owner buys thethinnest foam Building has no ceiling,neighbor still hears steps A better rule HOA rule:Delta IIC ≥ 25, orfield test ≥ 45 Pads comparedon the same test Rubber wins,quieter floor for real
Drawing 13. A single IIC number with no test conditions rewards the paperwork, not the product.

To be clear, the problem isn't one brand doing something wrong. Testing with a suspended ceiling is a normal, legitimate lab method, and the conditions are printed in the report. The problem is a rule that compares numbers from different setups as if they were the same thing.

Real Honolulu condo requirements

These are the seven Oahu buildings that publish an exact number. Notice how many different ways they write it:

Building Requirement What kind of number
Hawaiki Tower FIIC 55 living areas, FIIC 45 kitchen and bath Field test of your installed floor
Keola La'i IIC 70 after installation (checked at AIIC 53) Result in your unit
Ilikai IIC 62 or STC 59 Product test data
Island Colony IIC 65 Sample submitted with request
Waikiki Banyan IIC 65, plus a load limit Underlayment rating
Honolulu Park Place IIC 65 in the specifications Spec sheet
Century Center IIC 65 in the specifications Spec sheet, submitted with request

Full quotes, sources and dates are on our Honolulu condo flooring rules by building page. Rules change, so always get the current document from your AOAO.

Field sound testing on Oahu

A few buildings, like Hawaiki Tower and Keola La'i, judge your floor by a field test after it's installed. An acoustical consultant brings a tapping machine to your unit and a microphone to the unit below and measures FIIC or AIIC under ASTM E1007.

  • Cost: national guides put field impact testing at roughly $1,500–3,500 per tested floor. Expect Hawaii to land at or above the top of that range once travel and scheduling are included.
  • Who does it: acoustical consulting firms; Honolulu has local ones, such as CENSEO AV+Acoustics, whose noise reports appear in Hawaii state filings. Ask for ASTM E1007 testing and a signed report.
  • Why it matters for your choice: a field test measures what your neighbor actually hears. It doesn't care what the spec sheet said, which is exactly when a thicker rubber underlayment pays off.

Getting approved: how it works in Honolulu

  • Find the rule. It may be in the house rules, the bylaws, or only in the contractor packet. One building we checked has nothing in its house rules; the requirement lives in the contractor guide.
  • Send a request before work starts. Boards usually want the flooring and underlayment spec sheets or test report, and some want a physical sample. Installing without approval can be a rules violation.
  • Check weight limits. Some buildings also cap how heavy the finished floor may be; Island Colony, for example, limits floor weight per square foot. Tile and thick rubber add weight.
  • Field-test buildings are different. Where the rule is a result "after installation", approval of a product doesn't protect you; the finished floor has to pass.

Two honest routes

In our experience, most Honolulu boards approve a floor from the spec sheet alone. That leaves you two choices:

  • Fastest approval: a thin pad whose spec sheet shows your building's number for your type of floor. It gets you approved, but remember the ceiling it was tested with.
  • Quietest real floor: rubber, as thick as your floor allows. Choose this if you care about the neighbor below, if there was a noise complaint, or if your building does field tests.

How to read an underlayment test report in 60 seconds

Before you buy, or before your HOA approves, check five lines on the report or spec sheet:

Checklist on a test report: slab thickness, ceiling below, floor covering, lab or field, Delta IIC ACOUSTIC TEST REPORT Standard: ASTM E492 (lab) Slab: 6" concrete Ceiling: suspended, 3-5/8" studs Floor: vinyl plank 5 mm Result: IIC 72 Delta IIC: 26 1Lab or field? 2Slab like yours? 3Ceiling below? 4Your flooring? 5Delta IIC Example values. If line 3 says "suspended ceiling," expect 10–20 fewer points in a condo without one.
Drawing 14. The five things to look for. Line 3 is the one that explains most "IIC 72" claims.
  1. Lab or field? ASTM E492 is a lab test. ASTM E1007 (FIIC or AIIC) is a test in a real building.
  2. Slab thickness. 6" or 8" concrete is typical. A thicker slab scores higher.
  3. Ceiling below. "Suspended ceiling," "drop ceiling," "resilient channel" or "gypsum board" means points you won't get in a building without one.
  4. Floor covering. Results for carpet or engineered hardwood don't transfer to vinyl plank.
  5. Delta IIC. If it's listed, this is your best apples-to-apples comparison.

What to do if your HOA asks for IIC 65 or more

You don't have to fight your board. Bring them the facts and ask for a rule that actually protects the unit below. Here is a short note you can adapt:

Dear Board,

I'm replacing my flooring with vinyl plank and want to protect my downstairs neighbor. Our rule asks for IIC 65. Most products that list IIC 65 or more were tested with a suspended ceiling under the slab, which our building doesn't have, so the number doesn't describe what my neighbor will hear.

I'd like to install a vulcanized rubber underlayment (Regupol Sonus Core). On a fair, like-for-like test with vinyl plank (Delta IIC), the 10 mm version adds 28 points, more than typical thin foam pads (22–26), and rubber holds up for the life of the floor. The test report is attached.

Would the board accept a product by Delta IIC, or a field test meeting the building code's AIIC 45, instead of a single lab IIC number?

Thank you,
[Your name, unit number]

If the board still insists on the number, ask them which test and which ceiling it refers to. That one question usually opens the conversation.

Which floors work over Sonus Core rubber

Rubber underlayment isn't right under every floor. Here is how it fits, based on Regupol's technical data sheets and test reports:

Floor Sonus Core? How it's installed
Ceramic or porcelain tile, stone Yes, 5 mm and up Glue the rubber to the slab with Regupol TruBond 45-101 (that's what this adhesive is made for), then set the tile over it following Regupol's tile guide.
Engineered hardwood Yes, 3 mm and up Per Regupol's hardwood guide. Tested: 3 mm under 1/2" engineered hardwood on a 6" slab, IIC 55 without a ceiling (Delta IIC 25).
Laminate (floating) Yes, 3 mm Loose-laid under the floating floor, as Regupol tested it (Delta IIC 26).
Click vinyl plank (SPC / rigid core) Yes, if the plank maker allows it Regupol's technical data sheets list rigid core click vinyl (SPC & WPC) as an approved use for all four thicknesses, with click-vinyl lab tests for 3, 5 and 10 mm (below). Check the plank's own guide first: many makers cap a second underlayment at about 3 mm, and some don't accept recycled-rubber underlayments at all. COREtec's SPC guide, for example, says crumb rubber underlayments "are not an acceptable option."

Sonus Core under click vinyl: Regupol's lab results. 5.5 mm click vinyl over Sonus Core on a bare 6" concrete slab, no ceiling below. Each number is for the whole tested assembly (floor + underlayment + slab), not the underlayment alone:

The plank maker's rules still decide: if your vinyl's installation guide doesn't accept a rubber underlayment, its warranty rules apply, whatever the rubber's test results.

  • Moisture. Hawaii slabs carry moisture, and we recommend protecting every floor from it. Under floating floors, lay a 6-mil poly vapor barrier over the concrete (or use a pad with a built-in film). Under glued rubber, plastic sheeting can't be used, so the slab must be dry enough for the adhesive: TruBond's limit is 90% relative humidity or 10 lbs on a calcium chloride test. Test first and talk to us if it's wetter.
  • Isolate the edges. Leave the floor free of the walls and fill the gap with a perimeter isolation strip (Regupol makes ISO-2) or acoustic sealant, so footsteps don't travel into the walls.
  • Plan door heights. 5–12 mm of rubber raises the floor. Check door clearances and transitions before you order.
  • Read the guide. Regupol's Sonus Core installation guides cover tile and hardwood step by step.

Vinyl plank with a pad already attached: can you add underlayment?

Can I put underlayment under vinyl plank that already has an attached pad? Read the flooring's installation manual first. If the manual allows an additional underlayment, you can install one. If it doesn't, don't.

Does adding underlayment void the warranty? It can, if the manual forbids it. There's one common exception: when your HOA requires a specific rating, brand or product, you may have to install that underlayment no matter what the flooring manual says to get your renovation approved. In that case you'd be knowingly giving up the flooring warranty to meet the association's rule. Talk to us before you buy and we'll help you pick a plank and underlayment combination that satisfies both.

Tile, hardwood and laminate: the same story in Regupol's numbers

The ceiling effect isn't special to vinyl plank. Here are Regupol's own lab results for Sonus Core under other floors:

Floor + Sonus Core Slab No ceiling With insulated gypsum ceiling Report
Vinyl plank + core 10 6" IIC 59 (ΔIIC 28) — PDF
1/2" solid hardwood + core 3 8" IIC 54 — PDF
1/2" engineered hardwood + core 3 8" — IIC 74 PDF
Engineered hardwood + core 10 6" — IIC 72 PDF
1/4" ceramic tile + core 10 6" IIC 50 IIC 62 Data sheet PDF
Ceramic tile + core 5 (9/32" tile without the ceiling, 1/4" with it) 6" IIC 50 IIC 62 PDF · PDF
Laminate + core 3 6" IIC 56 (ΔIIC 26) — PDF

Hard tile scores lowest because it's rigid and rings when struck. That's why tile over a condo bedroom needs the thicker cores, and why we keep Sonus Core in our tile underlayment range too. Every Regupol report is on Regupol's test report library.

Best underlayment for vinyl plank in a Honolulu condo: our recommendation

Your floor What we suggest
Click vinyl plank (most condo jobs) The underlayment your plank's manual approves. If it allows rubber, Regupol Sonus Core 3 mm, 5 mm or 10 mm (all three tested under click vinyl). If it allows only thin foam, Nroro SoundBarrier or OmniChoice.
Laminate Regupol Sonus Core 3 mm, loose-laid.
Engineered hardwood Regupol Sonus Core 3 mm; 10 mm for maximum quiet.
Tile or stone Regupol Sonus Core 5 mm glued with TruBond; 10 mm or 12 mm over bedrooms.
Board accepts spec sheets and budget comes first Nroro SoundBarrier ($0.89 / sq ft) or OmniChoice, if your rule's number is on their sheet for your floor.

All four Sonus Core thicknesses are in stock in Honolulu. Tell us your floor and your building, and we'll match the pair before you buy.

Not sure which underlayment your building needs?

Bring us your AOAO rules. We'll compare them with the actual test reports and recommend an underlayment that works for your neighbor, your board and your budget. Regupol Sonus Core 3, 5, 10 and 12 mm are in stock in Honolulu.

Book a free in-home estimate and we'll measure, check your building's rule and quote the floor and underlayment together.

Visit our showroom at 1130 N Nimitz Hwy A-121, or call or text (808) 210-4807. Compare products in our underlayment selector, browse all underlayment for vinyl plank, or see the full Regupol line.

Frequently asked questions

What is a good IIC rating? The building code minimum between condo units is IIC 50 in a lab or 45 in a field test, and published Honolulu AOAO rules ask for IIC 62 to 70. Whether a number is good depends on how it was tested: lab results of 70 and up usually include a suspended ceiling, while 10 mm rubber under vinyl plank on a bare 6-inch slab tests at IIC 59.

What does IIC 70 mean? The whole floor-ceiling assembly scored 70 on the impact test. On a spec sheet it usually comes from a lab test with a suspended ceiling under the slab. Keola La'i, for example, requires IIC 70 after installation but checks finished floors at AIIC 53 in a field test.

What IIC rating do I need for a condo? The building code minimum between units is IIC 50 in a lab or 45 in a field test. Your AOAO may require more; check whether its number assumes a suspended ceiling.

Is a higher IIC always quieter? Only when both numbers come from the same test setup. A 72 measured with a suspended ceiling and a 59 measured without one can't be compared.

What's the difference between IIC and STC? IIC rates impact noise like footsteps. STC rates airborne noise like voices and TV. For hard floors, IIC is the one that matters most.

What is Delta IIC? The improvement an underlayment and floor add over bare concrete, measured without a ceiling. It's the fairest way to compare underlayments.

Why does a thin foam underlayment show IIC 72 or 73? Because it was tested on a concrete slab with a suspended drywall ceiling underneath, which adds about 10–20 points by itself. The same pad on a bare slab scores far lower.

Can any underlayment reach IIC 65 or 70 in a Honolulu condo? Not on its own in a typical concrete tower with no suspended ceiling. On a bare 6" slab, even 10 mm rubber under vinyl plank tested at IIC 59.

What is the difference between IIC and FIIC or AIIC? IIC is measured in a lab. FIIC and AIIC are measured in a real building and are usually lower, because sound also travels through walls and columns.

Is rubber underlayment better than foam? On a like-for-like test (Delta IIC with vinyl plank), Regupol Sonus Core 10 mm adds 28 points versus 22–26 for typical 1.5 mm foam pads, and dense rubber resists flattening over the life of the floor.

Which Regupol Sonus Core thickness should I use? Under click vinyl plank, Regupol approves all four thicknesses and has click-vinyl tests for 3, 5 and 10 mm (IIC 56, 56 and 59 on a bare 6" slab), but use only what the plank maker allows. 3 mm under laminate and hardwood, 5 mm and up glued under tile, and 10–12 mm where the floor allows it and you want maximum quiet.

Where can I buy Regupol Sonus Core in Hawaii? Best Flooring Honolulu stocks Sonus Core 3, 5, 10 and 12 mm at 1130 N Nimitz Hwy A-121, Honolulu. Call or text (808) 210-4807.

Do I need a moisture barrier over concrete? Yes, protect every floor from slab moisture. Under floating floors use a 6-mil poly barrier or a pad with a built-in film. Glued rubber under tile can't go over plastic, so the slab must test dry enough for the adhesive.

How do you install Regupol Sonus Core? Under tile, it's glued to the slab with Regupol TruBond 45-101 and the tile is set over it. Under floating laminate it's loose-laid. Under click vinyl plank, use it only if the plank maker allows it. Follow Regupol's installation guide for your floor.

How much does a field sound test cost? National guides put field impact testing (ASTM E1007) at roughly $1,500 to $3,500 per tested floor; Hawaii is usually at or above the top of that range.

How much more does rubber underlayment cost for a 1,000 sq ft condo? About $2,000 more: roughly $890 to $950 for 1.5 mm foam versus $2,940 for Regupol Sonus Core 10 mm, materials only.

Glossary

Decibel (dB) The unit for loudness. Every 10 dB sounds roughly twice as loud.
Impact noise Noise from something hitting the floor: footsteps, dropped objects, furniture.
Airborne noise Noise that travels through air first: voices, TV, music.
IIC Impact Insulation Class. Lab rating for footstep noise through a floor-ceiling assembly (ASTM E492).
FIIC / AIIC Field and Apparent IIC. The same idea measured in a real building (ASTM E1007).
ΔIIC (Delta IIC) How many IIC points an underlayment and floor add over bare concrete (ASTM E2179).
STC Sound Transmission Class. Lab rating for airborne noise (ASTM E90).
FSTC / NNIC Field versions of airborne ratings (ASTM E336).
Floor-ceiling assembly Everything between your feet and your neighbor's ears: flooring, underlayment, slab, and any ceiling below.
Suspended (drop) ceiling A drywall or tile ceiling hung below the slab with an air gap. Adds 10–20 IIC points.
Resilient channel Thin metal strips that hang drywall so it doesn't touch the structure directly.
Flanking Sound that bypasses the floor by traveling through walls, columns or pipes.
Decoupling Separating two layers with something soft so vibration can't pass straight through. It's what an underlayment does.
Vulcanized rubber Rubber cured with heat so it stays elastic and springs back under load.
AOAO Association of Apartment Owners, Hawaii's term for a condo HOA.

About the author. Borys Rasin has run Best Flooring Honolulu since 2017. We import and sell flooring and underlayment to homeowners and contractors across Oahu, from our Nimitz showroom and Waipio warehouse, and help owners get condo flooring approved under AOAO rules.

Sources: Regupol test reports for Sonus Core 3, 5, 10 and 12 (acoustics.regupol.us); Regupol Sonus Core 3, 5, 10 and 12 technical data sheets (Release 2/21/2025; 12 mm 9/1/2023); Honolulu AOAO house rules (see our building rules page); Commercial Acoustics field-testing cost guide; Nroro SoundBarrier SGS report; OmniChoice spec sheets; Regupol TruBond 45-101 technical data; COREtec Pro SPC installation guide; manufacturer spec sheets for 1.5 mm foam underlayments; ASTM E492, E1007 and E2179; International Building Code §1206.

November 19, 2026 — Borys Rasin

Leave a comment

Please note: comments must be approved before they are published.